Ametek ReFlex Programming Manual Manuel d'utilisateur Page 85

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 134
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 84
DC Module Remote Programming ReFlex Power™ Programming Manual
M380056-03 Rev L 81
3.14
TRIGGER SCPI COMMANDS
The SCPI commands associated with establishing external trigger signals are
listed in this section.
3.14.1
TRIGGER
SCPI
C
OMMAND
S
UMMARY
TRIGger<n>
:DISPlay?
:INP <t>
:OUTP <t>
:INP <t>, OUTP <t>
:OUTP <t>, INP <t>
:INPut:SLOPe [POSitive | NEGative | BOTH | NONE
1
]
:OUTput:SLOPe [POSitive | NEGative | BOTH]
:TRIG <t>
:WIDTh<+NRf>
3.14.2
T
RIGGER
SCPI
C
OMMAND
R
EFERENCE
Command
Description
TRIGger<n>
Trigger subsystem. <n> = module number.
:DISPlay?
Displays the module’s usage of the GPIO Buss signals,
that are used in the currently loaded List. See LIST below.
:
INP <t>
Establish that on module n, trigger t is an input. t = a-d, fa
(front panel only, in the DC module). (Non-pass through
mode.)
:
OUTP <t>
Establish that on module n, trigger t is an output. t = a-d,
fa. (Non-pass through mode.)
:
INP <t>, OUTP <t>
:
OUTP <t>, INP <t>
The RFP’s GPIO Buss signals (t = a, b, c, or d) connected
to ‘fa’, the Modules Front Panel trigger, specifying
direction. The trigger signal is passed through the Module.
:
INPut:SLOPe [POSitive |
NEGative | BOTH | NONE
1
]
Sets module n’s fa trigger input edge as positive, negative,
or both.
:
OUTPut:SLOPe [POSitive |
NEGative | BOTH]
Sets module n’s fa trigger output edge as positive,
negative, or both.
:
TRIG<t>
2
Generate a trigger from module n, t = a-d, fa.
:
WIDTh<+NRf>
n = Module number, sets Front Panel trigger output pulse
width in SLOPE POS / NEG mode. The WIDTh timing
range is 2.0e-6 to 2.097 seconds.
Note: At this time the ReFlex Power™ system only implements direct trigger mapping
‘a’ to ‘fa’, ‘b’ to ‘fb’, ‘c’ to ‘fc’ and ‘d’ to ‘fd.’
1
The
TRIG:SLOPe NONE
parameter disables the trigger and disconnects the ‘fx’ to ‘x’
connection.
2
The POSitive and NEGative trigger pulse’s on the Front Panel trigger output are not
retriggerable, if a trigger pulse is being produced, and another trigger out is
executed, it will be ignored, and no errors will be posted.