Fixed Power DC Remote Programming ReFlex Power™ Programming Manual
M380056-03 Rev L 123
6.
FIXED POWER DC REMOTE
PROGRAMMING
6.1
INTRODUCTION
This section covers the remote programming option for the ReFlex Power™
Fixed Power DC Module. This interface enables operation of the Fixed Power DC
from a computer via the Ethernet, allowing full remote programming control and
monitoring of the Fixed Power DC module.
6.2
FEATURES AND FUNCTIONS
F
EATURES
• Fixed Plus 5, Minus 5, Plus 15 and Minus 15 Volt Supply
• SCPI compliant command set
• Fixed Voltage Output
• Field-upgradeable firmware via Ethernet
• Soft calibration
P
ROGRAMMABLE
F
UNCTIONS
• Over/Undervoltage protection
• Output enable/disable
• Maskable fault interrupt
• Full calibration
R
EADBACK
F
UNCTIONS
• Status and Accumulated Status registers
• Programming error codes
• Fault codes
• Manufacturer, power supply model, serial number, and firmware
version identification