Fixed Power DC Remote Programming ReFlex Power™ Programming Manual
M380056-03 Rev L 123
6.
FIXED POWER DC REMOTE
PROGRAMMING
6.1
INTRODUCTION
This section covers the remote programming option for the ReFlex Power™
Fixed Power DC Module. This interface enables operation of the Fixed Power DC
from a computer via the Ethernet, allowing full remote programming control and
monitoring of the Fixed Power DC module.
6.2
FEATURES AND FUNCTIONS
F
EATURES
Fixed Plus 5, Minus 5, Plus 15 and Minus 15 Volt Supply
SCPI compliant command set
Fixed Voltage Output
Field-upgradeable firmware via Ethernet
Soft calibration
P
ROGRAMMABLE
F
UNCTIONS
Over/Undervoltage protection
Output enable/disable
Maskable fault interrupt
Full calibration
R
EADBACK
F
UNCTIONS
Status and Accumulated Status registers
Programming error codes
Fault codes
Manufacturer, power supply model, serial number, and firmware
version identification