ReFlex Power™ Programming Manual AC Module Remote Programming
98 M380056-03 Rev L
Command Description
:STATe <bool>
1
Set the initial POR output state of the unit
:STATe?
Query the initial POR output state setting of the unit
:FREQuency <NRi>
Set the initial frequency of the unit
:FREQuency?
Query the initial frequency of the unit
:DEFault
Set the initial value to default
:MODule
:LASTCAL <Date>
Set the last calibration date
:LASTCAL?
Query the last calibration date
:NEXTCAL <Date>
Set the next calibration date
:NEXTCAL?
Query the next query calibration date.
1
If CAL:INIT:STATe is 1’, the module will automatically turn on as if an OUTP:STATe
1 command had been received. This will only occur during initial power up, *RST will
only restore the saved CAL:INIT values. The unit will not automatically turn on if
enabled, after a *RST.