ReFlex Power™ Programming Manual DC Module Remote Programming
60 M380056-03 Rev M
3.8
OUTPUT SCPI COMMANDS
3.8.1 OUTPUT
SCPI
C
OMMAND
S
UMMARY
OUTPut[n]
:ISOLation <bool>
:DEFault <bool>
:DEFault?
:ISOLation?
:POLarity <NORM/0/OFF|INV/1/ON>
:POLarity?
:PROTection
:DELAY <NRf>
:DELAY?
:FOLD <NRi>
:FOLD?
:SENSe <bool>
:DEFault <bool>
:DEFault?
:SENse?
:STATe <bool>
:STATe?
:TRIPped?
:MODFault <bool>
:MODFault?
:CLEar <bool>
:CLEar?
:DPDelay
:TIMER <NRf>
:TIMER?
3.8.2 OUTPUT
SCPI
C
OMMAND
R
EFERENCE
Command
Description
OUTPut<n>
Output subsystem. Module ‘n’.
:ISOLation <bool>
Turns 1/ON or 0/OFF, the output isolation relay. The output
voltage must be set to zero prior to issuing this command. The
ISOL relay can’t be opened if Sense relay is closed.
:ISOLation?
Query the state of the ISOLation relay. 0 = open, 1 = closed.
:
DEFault <bool>
Sets DEFault state of ISOL Relay, POR default state is ON. The
ISOL/SENSe relays will be automatically sequenced during the
STATE command.
:
DEFault?
Query DEFault state of Isolation relay
:POLarity
<NORM/0/OFF | INV/1/ON>
Changes the state of the polarity relay. This command requires
that the isolation/sense relays be opened beforehand. If the
isolation relay is closed when this command is attempted, the
state of the polarity relay will not change, and an error message
Vue de la page 63