ReFlex Power™ Programming Manual Controller Module Remote Programming
36 M380056-03 Rev M
2.6.2 C
OMMUNICATION WITH THE
S
YSTEM
Click within the Net Test window (Figure 2-14) to begin control
communications by inputting SCPI commands per the proper syntax and
conventions described herein.
2.7
SCPI COMMAND OPERATION
The SCPI command sets provide programming, query, and status commands
that facilitate remote control of the ReFlex Power™ system.
The system supports the SCPI 1999.0 status reporting data structures. These
structures are comprised of status registers and status register enable mask
pairs. The following sections describe these pairs.
2.7.1 E
RROR
/E
VENT
Q
UEUE
The Error/Event Queue, defined by SCPI holds up to ten error events. Issue
the SYSTem:ERRor? query to read the queue in a First In/First Out (FIFO)
manner. The read operation removes the entry from the queue. Issue the
*CLS command to clear all entries from the queue.
The following SCPI-defined error codes are in the range of [-32768, 32767].
SCPI reserves the negative error codes and 0, while error codes greater than
0 are device-specific errors.