Ametek SFA Series Ethernet Programming Manuel d'utilisateur Page 99

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 159
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 98
SG Series Programming SCPI Command Operation
M550129-03 Rev K
6-27
6.12
CALIBRATION SCPI COMMAND SUBSYSTEM
Note: See Section 7 for calibration procedures.
CAUTION
Please refer to the power supply manual for further information before
performing calibration procedures. Calibration must be performed by qualified
personnel who appropriately deal with attendant hazards. If calibration is not
performed properly, functional problems could arise, requiring that the supply
be returned to the factory.
6.12.1
CALIBRATION SCPI Command Summary
CALibrate
:DATA <NRf><NRf><NRf><NRf><NRf><NRf><NRf><NRf><NRf><NRf>
:DATE <NRf>
(applies to GPIB; for Ethernet, see CAL:MOD:LASTCALDATE and CAL:MOD:NEXTCALDATE)
:DATE?
(applies to GPIB; for Ethernet, see CAL:MOD:LASTCALDATE and CAL:MOD:NEXTCALDATE)
:INITial
:CURRent <NRf>
:CURRent?
:MEASure:CURRent:AVErage <NR1>
:MEASure:CURRent:AVErage?
:VOLTage <NRf>
:VOLTage?
[:AMPLitude] <NRf>
[:AMPLitude?]
:PROTection <NRf>
:PROTection?
:MEASure
:CURRent
:ADC?
:CALCulate
:GAIN <NRf>
:GAIN?
:OFFSet <NRf>
:OFFSet?
:POINt <1|2> <NRf>
:VOLTage
:ADC?
:CALCulate
:GAIN <NRf>
:GAIN?
:OFFSet <NRf>
:OFFSet?
:POINt <1|2> <NRf>
:MODel
:LASTCALDATE
(applies to Ethernet only; for GPIB, see CAL:DATE)
:LASTCALDATE?
(applies to Ethernet only; for GPIB, see CAL:DATE?)
:NEXTCALDATE
(applies to Ethernet only)
:NEXTCALDATE?
(applies to Ethernet only)
:POWERON
:POWERON?
:RESET
Vue de la page 98
1 2 ... 94 95 96 97 98 99 100 101 102 103 104 ... 158 159

Commentaires sur ces manuels

Pas de commentaire