SCPI Command Operation SG Series Programming
6-48 M550129-03 Rev K
PROG:STAT COMPLETE
PROG:SAVE:SEL
PROG:STAT?
Response: Ram[0]=“STOPPED”,Slave[0]=”STOPPED”
Once in the STOPPED state, the sequence is ready to run again. To rerun the sequence,
issue the following two commands:
OUTP:STAT ON
PROG:STATE RUN
The sequence should run, and the output of the power supply for Example 1 should look
like the following:
Figure 6-1. Power Supply Output for Example 1
Leave SEQ1 in the power supply’s sequence memory, and create a second example
sequence to also keep in sequence memory. (There is enough memory for a total of 50
different sequences.)
EXAMPLE 2
Issue *RST to establish a known state.
PROG:NAME SEQ2
PROG:MALL DEFAULT
PROG:DEF 1, VIMODE,10,4,11,5 //go to 10 volts, 4 amps, 11 volts ovp, for 5
seconds
PROG:DEF 2, RAMPTOV,10,2,4,11,9 //ramp from 10 volts down to 2 volts in 10 seconds
PROG:DEF 3,RETURN
PROG:STAT COMPLETE
PROG:SAVE:SEL
PROG:STAT?
Response: Ram[22]=“STOPPED”,Slave[22]=”STOPPED”
3 volts for 10 sec
3 volts for 10 sec
5 volts for 10 sec
Ramp up to 5
volts in 10 sec
Ramp down to 3
volts in 10 sec