Ametek SFA Series Ethernet Programming Manuel d'utilisateur Page 145

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 159
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 144
SG Series Programming Calibration
M550129-03 Rev K
7-11
7.8
ANALOG PROGRAM ADJUSTMENT
This sections applies only to units with the Isolated Interface Adapter *(IIA)
option.
All calibration potentiometers can be adjusted through access holes in the top
cover of the SGI Series unit. It is not necessary to remove the top cover to
perform the calibration procedure. Please refer to Figure 7-1 when following
the adjustment procedures.