Ametek BPS Series Programming Manual Manuel d'utilisateur Page 83

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 226
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 82
BPS / MX / RS Series SCPI Programming Manual AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA 83
FREQuency:SLEW:TRIGgered
This command sets the rate at which frequency changes during a triggered output transient.
Instantaneous frequency changes can be obtained by sending MAXimum.
Command Syntax [SOURce:]FREQuency:SLEW:TRIGgered <NRf+>
Parameters 0.01 to 1E9MAXimum
Unit Hz (Hertz per second)
*RST Value MAXimum
Examples FREQ:SLEW:TRIG 75 FREQ:SLEW:TRIG MAX
Query Syntax [SOURce:]FREQuency:SLEW:TRIG?
Returned Parameters <NRf>
Related Commands FREQ:SLEW:MODE FREQ
FREQuency:TRIGgered
This command programs the frequency that the output will be set to during a triggered step
or pulse transient.
Command Syntax [SOURce:]FREQuency:TRIGgered <NRf+>
Parameters 0 to maximum frequency range specified by the LIMit:FREQuency
command
Unit Hz (Hertz)
*RST Value 60 Hz
Example FREQ:TRIG 50
Query Syntax [SOURce:]FREQuency:TRIGgered?
Returned Parameters <NR2>
Related Commands FREQ FREQ:MODE