Vue de la page 199
AMETEK Programmable Power BPS / MX / RS Series SCPI Programming Manual
200 Manual P/N 7003-961 Rev AA
8.10 OMNI Reference Impedance
The OMNI remote programming syntax is part of the Output subsystem.
Subsystem Syntax
OUTPut
:OMNI
[:STATe]<state> Select the OMNI state (BYPassed|ENGaged)
OUTPut:OMNI[:STATe]
This command will engage or bypass the OMNI impedance network. The output voltage will
drop when the state changes.
Command Syntax OUTPut:OMNI[:STATe]<state>
Parameters BYPassed | ENGaged
*RST Value BYPassed
Examples OUTP:OMNI ENG
Query Syntax OUTPut:OMNI[:STATe]?
Returned Parameters BYP|ENG
Related Commands None