4.13 Source Subsystem - Frequency
This subsystem programs the output frequency of the AC/DC source.
Subsystem Syntax
[SOURce:]
FREQuency
:IMMediate] <n> Sets the frequency
:MODE <mode> Sets frequency mode
(FIX|STEP|PULS|LIST|SENS|EXT)
:SLEW
[:IMMediate] <n> | MAXimum Sets the frequency slew rate
:MODE <mode> Sets frequency slew mode
(FIX|STEP|PULS|LIST)
:TRIGgered <n> | MAXimum Sets the triggered frequency slew rate
:TRIGgered <n> Sets the triggered frequency
FREQuency
This command sets the frequency of the output waveform.
Command Syntax [SOURce:]FREQuency[:CW|:IMMediate] <NRf+>
Parameters Refer to specifications table in User Guide
Unit Hz (Hertz)
*RST Value 60 Hz
Examples FREQ 50
Query Syntax [SOURce:]FREQuency?
Returned Parameters <NR3>
Related Commands FREQ:MODE FREQ:SLEW
FREQuency:MODE
This command determines how the output frequency is controlled. The choices are:
FIXed The output frequency is unaffected by a triggered output transient.
STEP The output frequency is programmed to the value set by
FREQuency:TRIGgered when a triggered transient occurs.
PULSe The output frequency is changed to the value set by
FREQuency:TRIGgered for a duration determined by the pulse commands.
LIST The output frequency is controlled by the frequency list when a triggered
transient occurs.
SENSe Selects external sync mode.
EXTernal Selects external clock input.
Command Syntax [SOURce:]FREQuency:MODE <mode>
Parameters FIXed | STEP | PULSe | LIST|SENSe|EXT
*RST Value FIXed
Examples FREQ:MODE FIX
Query Syntax [SOURce:]FREQuency:MODE?
Returned Parameters <CRD>
Related Commands FREQ FREQ:TRIG