Ametek BPS Series Programming Manual Manuel d'utilisateur Page 113

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 226
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 112
BPS / MX / RS Series SCPI Programming Manual AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA 113
4.23 Status Subsystem Commands
This subsystem programs the AC/DC power source status registers. There are four groups
of status registers;
Operation Status Group
Questionable Status Group
Questionable Instrument Isummary Group
Standard Event Group
The Standard Event group is programmed with Common commands. The Operation,
Questionable, and Instrument ISummary status groups each consist of the following three
registers:
Condition Enable Event
Refer to chapter 7 for more information about the status registers.
Subsystem Syntax
STATus
:OPERation
:EVENt Returns the value of the event register
:CONDition Returns the value of the condition register
:ENABle <n> Enables specific bits in the Event register
:QUEStionable
:EVENt Returns the value of the event register
:CONDition Returns the value of the condition register
:ENABle <n> Enables specific bits in the Event register
:INSTruments
:ISUMmary
:EVENt Returns the selected phase’s event register value
:CONDition Returns the selected phase’s condition register
:ENABle Enable specific bits in selected phase’s Event
register values
Bit Configuration of Status Operation Registers
Bit Position 15-5 4 3 1-2 0
Bit Name not used MEAS TRANS not used CAL
Bit Weight 16 8 1
CAL Calibration is completed
TRANS Transient is completed
MEAS Measurement is completed
Vue de la page 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 225 226

Commentaires sur ces manuels

Pas de commentaire