Ametek BPS Series Programming Manual Manuel d'utilisateur Page 168

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 226
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 167
AMETEK Programmable Power BPS / MX / RS Series SCPI Programming Manual
168 Manual P/N 7003-961 Rev AA
7.3 Questionable Status Group
The Questionable Status registers record signals that indicate abnormal operation of the AC
source. As shown in Figure 7-1, the group consists of the same type of registers as the
Status Operation group.
Register Command Description
Condition STAT:QUES:COND? A register that holds real-time status of the
circuits being monitored. It is a read-only
register.
Event STAT:QUES:EVEN? A register that latches any condition. It is a
read-only register that is cleared when read.
Enable STAT:QUES:ENAB <n> A register that functions as a mask for
enabling specific bits from the Event
register. It is a read/write register.
Table 7-3: Questionable Status Register
The outputs of the Questionable Status group are logically-ORed into the QUEStionable
summary bit (3) of the Status Byte register.
Vue de la page 167
1 2 ... 163 164 165 166 167 168 169 170 171 172 173 ... 225 226

Commentaires sur ces manuels

Pas de commentaire