Ametek SFA Series Programming Manual Manuel d'utilisateur Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
Sorensen SF Series IEEE 488.2 and SCPI Command Operation
3.9
3.9.1
3.9.2
SYSTEM SCPI Command Subsystem
SYSTEM SCPI Command Summary
SYSTem
:ERRor?
:FAULt?
:VERsion?
:LOCAL <boolean>
:LOCAL?
:LOCLOUT <boolean>
SYSTEM SCPI Command Reference
In the following table a "C" in the SCPI column indicates that the command is SCPI-compliant.
The Q? column indicates whether the command can also be used for querying.
Command Description SCPI Q?
SYSTem
System subsystem. C
:ERRor?
Queries Error Queue for next error/event entry
(first in, first out). Entries contain an error
number and descriptive text. A 0 return value
indicates no error occurred; negative numbers
are reserved by SCPI. The maximum return
string length is 255 characters. The queue
holds up to 10 error/entries. All entries are
cleared by the *CLS command.
C
:FAULt?
Returns four numeric values separated by
commas for the four system fault registers. See
System Fault Registers below. Valid response
is 128, 0, 0, 0 or 0, 0, 0, 0.
Response: <Fault1–8>, <Fault9–16>,
<Fault17–24>, <Fault25–31>
N
:VERsion?
Returns a numeric value corresponding to the
SCPI version number for which the instrument
complies. The response is in the format
YYYY.V where the Y’s represent the year and
V represents the approved version number for
that year (e.g., 1995.0)
C
M550292-03 (Programming) 3-17