Ametek SFA Series Programming Manual Manuel d'utilisateur Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
IEEE 488.2 and SCPI Command Operation Sorensen SF Series
3.7
3.7.1
3.7.2
OUTPUT SCPI Command Subsystem
OUTPUT SCPI Command Summary
OUTPut
:PROTection
:DELay <0+NRf>
:DELay?
:FOLD <0|1|2>
:FOLD?
:STATe <boolean>
:STATe?
:TRIPped?
OUTPUT SCPI Command Reference
In the following table a "C" in the SCPI column indicates that the command is SCPI-compliant.
The Q? column indicates whether the command can also be used for querying.
Command Description SCPI Q?
OUTPut
Output subsystem. C
:PROTection
N
:DELay <0+NRf>
Sets the programmable time delay executed
by the supply before reporting output
protection conditions after a new output
current is specified.
N Q
:FOLD <0|1|2>
Sets the foldback (program down) mode of
the supply. Valid arguments are 0 (OFF or do
nothing, do not program down to zero), 1(Not
used), or 2 (program down to zero upon
entering constant-current mode).
N Q
:STATe <boolean>
Sets the output to zero or the programmed
value. Valid arguments are 1/ON or 0/OFF.
*RST state value is ON.
C Q
:TRIPped?
Returns the integer value 1 (TRIPPED) or 0
(UNTRIPPED) state of the output.
N
3-14 M550292-03 (Programming)
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 47 48

Commentaires sur ces manuels

Pas de commentaire