Programming Manual Lx \ Ls Series II
44
B and C (ø1, ø2 and ø3). If the MODE field is set (standard on Lx Series,
optional on Ls Series) the AC source can operate in both 1 and 3 phase
modes.
Other
Any value other than 0 or 120 indicates 2 phase configuration with phase
angle between A and B set to value shown.
Query Syntax LIMit:PHASe?
Returned Parameters <NR3>
Examples LIM:PHAS?
Related Commands SYST:CONF:NOUT?
LIMit:VOLTage:HIGH
Query form returns the maximum available output voltage for the high voltage range. This value
determines the maximum AC RMS voltage available using a sinusoidal waveform. Note that this
is not the same as the available maximum voltage, which is a function crest factor of the voltage
waveform. To query the maximum available voltage, use the VOLT? MAX command.
Query Syntax LIMit:VOLTage:HIGH?
Returned Parameters <NR3>
Examples LIM:VOLT:HIGH?
Related Commands LIM:VOLT:LOW?
LIMit:VOLTage:LOW
Query form returns the maximum available output voltage for the low voltage range. This value
determines the maximum AC RMS voltage available using a sinusoidal waveform. Note that this
is not the same as the available maximum voltage, which is a function crest factor of the voltage
waveform. To query the maximum available voltage, use the VOLT? MAX command.
Query Syntax LIMit:VOLTage:LOW?
Returned Parameters <NR3>
Examples LIM:VOLT:LOW?
Related Commands LIM:VOLT:HIGH?