8.4.3 DO160 Emergency Test Commands
DO160:EMERgency:VOLT_FREQ:MINimum
This command will set the voltage and frequency to the minimum level for the emergency
operation.
Command Syntax DO160:EMERgency:VOLT_FREQ:MINimum
Parameters none
Examples DO160:EMER:VOLT_FREQ:MIN
Query Syntax none
DO160:EMERgency:VOLT_FREQ:MAXimum
This command will set the voltage and frequency to the maximum level for the emergency
operation.
Command Syntax DO160:EMERgency:VOLT_FREQ:MAXimum
Parameters none
Examples DO160: EMER:VOLT_FREQ:MAX
Query Syntax none
DO160: EMERgency:VOLTage:UNBalance
This command will unbalance the voltage level for each phase to the emergency high and low
operating voltage of each phase. This test is valid only for three phase AC source.
Command Syntax DO160:EMERgency:VOLTage:UNBalance
Parameters none
Examples DO160: EMER:VOLT:UNB