Interface Manual
Continuous Level Controls
ABSOLUTE PROCESS CONTROL
KNOW WHERE YOU ARE... REGARDLESS
TM
7100
Leak Detect Stik
Magnetostrictive LeveL systeM
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - Leak Detect Stik

Interface ManualContinuous Level ControlsABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESSTM7100 Leak Detect Stik™Magnetostrictive LeveL

Page 2

8Chapter 2: Interfacing to ProbeThe pulse signals coming from the probe are superimposed onto the nominal 24 VDC power supply connections. As shown in

Page 3 - Contents

9NOTE 1: ts-s = time from 1st start pulse in one frame to next start pulse in the next frame.NOTE 2: Start pulse can start anywhere in the 4.5 ms fr

Page 4 - 1.1: Data Protocol

102.1: Interface HardwareA typical console has the following sub-systems: 1. Probe Mulitplexer 2. Intrinsic Safety Barrier 3. Pulse Discriminator

Page 5 - 1.2: Frame Protocol

11Figure 7: Typical Console Circuitry-+Comparator+1 VDCReferenceAlways use the leading edgeCounter Gating CircuitHigh Speed CountersHigh Speed Clock (

Page 6

12Chapter 3: Getting the DataThe method that data is communicated between the probe and the console is described in Section 1.1: Data Protocol. The us

Page 7

133.3: System Software SetupAlthough one frame of data is sufcient to obtain valid product, water, and temperature readings, averaging multiple frame

Page 8

14Chapter 4: Processing the DataData acquisition was discussed in Section 3 to the degree that memory locations are lled with an array of data from a

Page 9

15Chapter 5: Computing the TemperatureA probe reading contains 15 values for product, water and temperature. The product and water values are each use

Page 10 - Pulse Pair

16Step 3 - Using the attached table, nd the linear temperature interval (TLIN1, TLIN2) and then the actual temperature interval (T1, T2) for TLIN.Exa

Page 11 - High Ref

17Temperature Calculation TableActual Temp °CLinear Temp °CActual Temp °CLinear Temp °CActual Temp °CLinear Temp °CActual Temp °CLinear Temp °CActual

Page 13

18EC Declaration of Conformity Manufacturer:AMETEK Automation & Process Technologies 6380 Brockway Road, Peck, MI 48466 USA Identification of Eq

Page 15 - 3.3: System Software Setup

MADE IN AMERICAOther Products© Copyright 2013. All Rights Reserved. Made in the USA. ®1080 North Crooks Road, Clawson, MI 48017 Phone: 248-435-0700

Page 16 - 4.1: Front End Algorithm

ContentsChapter 1: Description of Probe ...21.1 Data Protocol ...21.2 Frame

Page 17

2Chapter 1: Description of ProbeThe 7100 liquid level probe uses a proprietary data transmission technique providing a compact information format for

Page 18

31.2: Frame ProtocolAll 7100 probes transmit data in the same general format. In this format, information is conveyed during a discrete period of time

Page 19

4The type of information contained in each reading varies depending on the probe type. Table 2 species the data pattern for various probe types.Table

Page 20 - EC Declaration of Conformity

57100 Flex Stik Installation Drawing1.3: Installation and Dimension Drawings

Page 21

67100 Dimension Drawing, Page 1

Page 22 - Other Products

77100 Dimension Drawing, Page 2

Commentaires sur ces manuels

Pas de commentaire