Ametek DCS-E 1kW Series Programming Manual Manuel d'utilisateur Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
DLM-E Series and DCS-E Series Isolated Analog Programmer Operation
2.3.9 Programming the Shutdown Function
2
13
1
25
15
+5V
GND
14
Figure 2–3. Using Shutdown with a DC Input (Positive Logic)
2.3.10 TTL Shutdown
Set up for Shutdown input signal as follows:
1. Connect the shutdown signal source to the ISOLATED ANALOG PROGRAMMER
connector, J4, with positive to Pin-14 and the return to Pin-2.
2. Set switch SW1-6 to select the desired logic as defined in the following table.
Switch SW1-6 Setting Signal Level Output Condition
Low OFF
OFF (0) = Negative Logic
High ON
High OFF
ON (1) = Positive Logic
Low ON
M51A Option 2-15
Vue de la page 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32

Commentaires sur ces manuels

Pas de commentaire