Isolated Remote Analog Interface Operation DLM 600W Series
2-12 M51A Option
2.7 Remote Digital Status Signals
Digital signals are available for remote monitoring the operational status of the unit. Refer to
Table 2–5 for information on the characteristics of the signals.
ISOLATED ANALOG
INTERFACE Connections
Logic Levels (with No
Signal Output Current)
Status
Indicator
Signal
Signal Return Asserted Not Asserted
Output
Resistance
VOLTAGE-
MODE
Pin-5 Pin-6 5V 0V 2k
OVP Pin-17 Pin-6 5V 0V 2k
FAULT Pin-18 Pin-6 5V 0V 2k
Table 2–5. Remote Digital Status Signals